Home > Product > Vortex flow meter > Rosemount

Rosemount

Contact us

TEL: 001-646-569-9958
FAX: 001-646-569-9958
Add:245 E MAIN ST STE 115,ALHAMBRA CA 91801,USA
> Read more

Rosemount

Rosemount 8800 CriticalProcess Vortex Flowmeter

Rosemount ®
8800 CriticalProcess™ Vortex Flowmeter
Summary:

The Rosemount CriticalProcess™ Vortex is designed to increase plantavailability and enhance overall safety.  This feature allows users toverify the performance of the Vortex sensor while providing an added level ofsafety on critical applications.

The CriticalProcess™ Vortex provides:

  • A unique design thatisolates the Vortex sensor from the process

  • The ability for onlinemaintenance of the Vortex sensor

  • A way to eliminateunnecessary process shutdowns, increasing availability without requiring bypasspiping

The Vortex sensor in the Rosemount 8800D Vortex Flowmeter is isolatedfrom the process making it possible to maintain the performance of the sensoronline, greatly increasing process availability.  Sensor maintenance canbe costly with traditional Vortex flowmeters. Unlike the 8800D, wetted Vortexsensor designs require that the process be shutdown or the meter bypassed toperform Vortex sensor maintenance.  The CriticalProcess™ Vortex eliminatesthis requirement, increasing availability and enhancing overall safety.

Features & Benefit

On-line Flowmeter Maintenance Capability

 

Increase Availability

The Vortex sensor in the Rosemount 8800D Vortex Flowmeter is isolated from the process making it possible to maintain the performance of the sensor online, greatly increasing process availability. Vortex sensor maintenance can be costly on traditional vortex meters where users are required to shutdown or bypass their process. The CriticalProcess™ Vortex enhances the user's ability to maintain the Rosemount 8800D Vortex flowmeter on-line. This eliminates the need for a shutdown or additional piping to bypass the process around the flowmeter.

The CriticalProcess™ Vortex enhances safety by providing a method to verify plant personnel will not be exposed to process fluids while performing on-line maintenance and troubleshooting on the Rosemount 8800D Vortex Flowmeter.

  Benefit/Value

  Example of Value

Reduce Installed Cost

·         Reducer™ Vortex eliminates the need for additional reducers

·         CriticalProcess™ Vortex eliminates the need for bypass piping

Improve Safety, Health & Environment

·         Eliminates need to break process seals

·         CriticalProcess Vortex verifies secondary containment integrity

·         Simplifies proof testing in SIL

Measurement Availability

·         On-line meter verification ensures transmitter electronics

·         CriticalProcess Vortex enable on-line sensor verification

 

 
Specifications
 

Key Specifications

Flowmeter Accuracy

± 0.65 % of rate for liquids
± 1% of rate for gas and steam

Turndown

38:1

Output 

·         4-20 mA with HART®

·         4-20 mA with HART® and Scalable Pulse Output

·         FOUNDATION™ fieldbus with 2 Analog Input blocks, 1 Backup Link Active Scheduler function block, and 1 Integrator function block (1 PID function block optional)

Wetted Material

Stainless Steel - 316 ⁄ 316L and CF3M
Nickel Alloy- C-22 and CW2M
Consult factory for other wetted material options

Flange Options

ANSI Class 150 to 1500
DIN PN 10 to PN 160
JIS 10K to 40K
Flanges are available in a variety of facings

Operating Temperatures

-330°F to 800°F (-200°C to 427°C)

Line Size

Flanged - ½-in to 12-in (15 to 300 mm)
Dual - ½-in to 12-in (15 to 300 mm