Micro Motion
Contact us
TEL: 001-646-569-9958
FAX: 001-646-569-9958
E-mail: services@myjackwell.com
Add:245 E MAIN ST STE 115,ALHAMBRA CA 91801,USA
Micro Motion
Micro Motion 2700 Field And Integral-Mount Multivariable Flo

- Output variables
-
Mass & volume flow
Net product content / flow
Temperature
Density
Concentration
- Local display
-
Standard user interface with 2-line LCD panel
Two optical switches for local operation
Glass or plastic lens options
- Power
-
Self-switching AC/DC input, automatically recognizes supply voltage
85 to 265 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum
18 to 100 VDC, 6 watts typical, 11 watts maximum
Complies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2, and Installation (Overvoltage) Category II, Pollution Degree 2
- Input/output signals
-
-
Not intrinsically safe
Analog output option:- One active 4–20 mA output
-
One active frequencty output
Frequency output can be configured as a discrete output
Configurable I/O option:- One or two active 4-20 mA outputs
- One or two active/passive frequency outputs
- One or two active/passive discrete outputs
- One discrete input
- Intrinsically safe
-
- One passive 4-20 mA output
- One passive frequency output
- Frequency output can be configured as a discrete output
Foundation™ fieldbus (Obsolete)
-
- optionally non-incendive
- One Foundation fieldbus H1 output
-
- One PROFIBUS-PA output
Analog output option:
PROFIBUS-PA (Obsolete) -
Not intrinsically safe
- HART/WirelessHART
-
Bell 202 signal is superimposed on the primary milliamp output
WirelessHART available via THUM adapter
HART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions
- Mounting options
-
Field-mount
- Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor
- Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
- Application types
-
Continuous process control
Custody transfer
Two-phase flow/entrained gas
Meter verification
SIS Certified
- Hazardous approvals
-
Class I, Div. 1
Class I, Div. 2
Zone 1
Zone 2
- HART/WirelessHART
-
Bell 202 signal is superimposed on the primary milliamp output
WirelessHART available via THUM adapter
HART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions
- Mounting options
-
Field-mount
•Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor
•Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
- Application types
-
Continuous process control
Custody transfer
Two-phase flow/entrained gas
Meter verification
SIS Certified
- Hazardous approvals
-
Class I, Div. 1
Class I, Div. 2
Zone 1
Zone 2