Home > Product > Pressure Transmitter > Yokogawa

Yokogawa

Contact us

TEL: 001-646-569-9958
FAX: 001-646-569-9958
Add:245 E MAIN ST STE 115,ALHAMBRA CA 91801,USA
> Read more

Yokogawa

YOKOGAWA EJA510A Absolute and Gauge Pressure Transmitters

YOKOGAWA ®
EJA510A, EJA530A Absolute and Gauge Pressure Transmitters
Summary:
EJA510A, EJA530A Absolute and Gauge Pressure Transmitters 
The absolute and gauge pressure transmitter model EJA510A and EJA530A can be used to measure liquid, gas, or steam pressure. Both output a 4 to 20mA DC signal corresponding to the measured pressure.
The EJA Series is available with BRAIN, HART, FOUNDATION™ fieldbus or PROFIBUS PA communication protocols.
 
Downloads for EJA510A/EJA530A
 
Features
Excellent performance and stability
The EJA series uses a silicon resonant sensor formed from monocrystal silicon, a perfect material which has no hysteresis in pressure or temperature changes. The sensor minimizes overpressure, temperature change, and static pressure effects, and thus offers unmatched long-term stability.
Compact and light-weight design
Half the weight of conventional models thanks to miniaturization of the casing with the amplifier ASIC, pressure cell structure, and flange. The ASIC uses the minimum number of parts and improves the reliability of the amplifier.
Fieldbus communication capability
Fieldbus is a digital two-way communication system. It is a revolutionary technology for configuring instrumentation control systems and a promising successor to the standard 4 to 20 mA analog communication used in most field instruments today.EJA series offers two types of fieldbus models, FOUNDATION™ fieldbus Low Voltage Mode and PROFIBUS PA devices, which ensure interoperability between Yokogawa and other manufactures. As for software, the EJA series incorporates two AI function blocks that compute differential and static pressures to allow flexible configuration of instrumentation.
 
Specifications
  EJA510A / EJA530A Direct Mount Type Absolute Pressure and Gauge Pressure Transmitter
(Measurement values below are in absolute for EJA510A)
A Capsule B Capsule C Capsule D Capsule
Range 0 to 200 kPa 0 to 2 MPa 0 to 10 MPa 0 to 50 MPa
(0 to 29 psi) (0 to 290 psi) (0 to 1450 psi) (0 to 7200 psi)
Span 10 to 200 kPa 0.1 to 2 MPa 0.5 to 10 MPa 5 to 50 MPa
(1.45 to 29 psi) (14.5 to 290 psi) (72.5 to 1450 psi) (720 to 7200 psi)
Accuracy ±0.2% ±0.2% ±0.2% ±0.2%
Degrees of protection IP67, NEMA 4X, and JIS C0920 immersion proof
Certificates FM, CENELEC ATEX, CSA, IECEx
Output 4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication
Supply voltage BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model)
Ambient temperature -40 to 85 deg C (-40 to 185 deg F) (general use type)
-30 to 80 deg C (-22 to 176 deg F) (with integral indicator)
Process temperature -40 to 120 deg C (-40 to 248 deg F) (general use type)
Maximum overpressure 4 MPa 4 MPa 20 MPa 60 MPa
(580 psi) (580 psi) (2900 psi) (8500 psi)
Mounting Direct Mounting/2-inch pipe mounting
Wetted parts material Capsule Hastelloy C-276
Process SUS316L, Hastelloy C-276
connection
Housing Cast aluminum